Navair Logo

The following tests were performed by the QPL Lab as designated in the Request for Samples for Retention of Qualification Testing of AS6070/5 and /6 NAVAIR letter dated 6 June 2016. Samples provided passed all testing as required in the AS6070 Specification.

Gasket on Glass-Lined Steel Flange (EN)

GORE Universal Pipe Gasket (Style 800): Gasket on Glass-Lined Steel Flange. To achieve a reliable seal, adequate gasket stress must be applied during installation. This table provides an estimation of torque for use during assembly of standard pipe flanges.

Torque Table for Ring or Full Face Gasket on Raised Face Steel Flange

GORE Universal Pipe Gasket (Style 800) & GORE GR Sheet Gasketing: Ring or Full Face Gasket on Raised Face Steel Flange. To achieve a reliable seal, adequate gasket stress must be applied during installation. This document provides an estimation of torque for use during assembly of standard design steel pipe flanges.

exposing

These procedures should be used as a guide in conjunction with current connector manufacturing instructions.

installation simulator design

Describes the components of Gore’s Installation Simulator that replicates the rigorous conditions a microwave airframe assembly experiences while being routed during installation in an aircraft.

Inspect, Reuse, Repair Guide

The following procedures are based on Gore’s best practices for inspecting, reusing, and repairing GORE™ SKYFLEX™ Aerospace Materials.

Lectromec Certified logo

AS4373 Test Report - DXN2603

测试数据, 104.84 KB

Test Report prepared for Gore Cable Part # DXN2603

exposing wire

These procedures should be used as a guide in conjunction with current connector manufacturing instructions.

return loss

Includes performance results for a 10-meter cable assembly with a plug and receptacle connector based on RCN9034-24.

Subscribe to Content
Top